Testing, SS-EN ISO/IEC 17025:2018

Latest decision date: 2025-06-18

TeknikområdeMetod/procedurProvtyp/System/ProduktParameter/EgenskaperUtrustning/MätprincipMätområde/mätnivå
Inorganic chemistrySS EN ISO 17294-1:2024/SS EN ISO 17294-2:2023Drinking waterMagnesium, MgICP-MS0,05 – 10 mg/l
Inorganic chemistrySS EN ISO 17294-1:2024/SS EN ISO 17294-2:2023Fresh waterMagnesium, MgICP-MS0,05 – 10 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023-Hardness, totalCalculation-
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterAluminum, AlICP-MS0,001– 1 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterAntimony, SbICP-MS0,05 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterArsenic, AsICP-MS0,05 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterBarium, BaICP-MS0,5 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterBismut, BiICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterBoron, BICP-MS5 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterCadmium, CdICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterCalcium, CaICP-MS0,1 – 50 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterChromium, CrICP-MS0,1 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterCobalt, CoICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterCopper, CuICP-MS0,1 – 1000 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterIron, FeICP-MS0,001 – 10 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterLead, PbICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterManganese, MnICP-MS0,001 – 1 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterMercury, HgICP-MS0,01 – 0,8 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterMolybdenum, MoICP-MS0,05 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterNickel, NiICP-MS0,1 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterPotassium, KICP-MS0,05 – 10 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterSelenium, SeICP-MS0,1 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterSodium, NaICP-MS0,05 – 50 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterStrontium, SrICP-MS0,1 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterUranium, UICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterVanadium, VICP-MS0,1 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Drinking waterZinc, ZnICP-MS1 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterAluminum, AlICP-MS0,001– 1 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterAntimony, SbICP-MS0,05 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterArsenic, AsICP-MS0,05 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterBarium, BaICP-MS0,5 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterBismut, BiICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterBoron, BICP-MS5 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterCadmium, CdICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterCalcium, CaICP-MS0,1 – 50 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterChromium, CrICP-MS0,1 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterCobalt, CoICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterCopper, CuICP-MS0,1 – 1000 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterIron, FeICP-MS0,001 – 10 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterLead, PbICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterManganese, MnICP-MS0,001 – 1 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterMercury, HgICP-MS0,01 – 0,8 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterMolybdenum, MoICP-MS0,05 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterNickel, NiICP-MS0,1 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterPotassium, KICP-MS0,05 – 10 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterSelenium, SeICP-MS0,1 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterSodium, NaICP-MS0,05 – 50 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterStrontium, SrICP-MS0,1 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterUranium, UICP-MS0,01 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterVanadium, VICP-MS0,1 – 10 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023Fresh waterZinc, ZnICP-MS1 – 100 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023/EPA Method 3015A rev 1Waste water/Leach waterAluminum, AlICP-MS0,04 – 4 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023/EPA Method 3015A rev 1Waste water/Leach waterCadmium, CdICP-MS0,1 – 40 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023/EPA Method 3015A rev 1Waste water/Leach waterChromium, CrICP-MS0,5 – 25 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023/EPA Method 3015A rev 1Waste water/Leach waterCopper, CuICP-MS1 – 1000 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023/EPA Method 3015A rev 1Waste water/Leach waterIron, FeICP-MS0,1 – 40 mg/l
Inorganic chemistrySS-EN ISO 17294-2:2023/EPA Method 3015A rev 1Waste water/Leach waterLead, PbICP-MS0,1 – 40 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023/EPA Method 3015A rev 1Waste water/Leach waterMercury, HgICP-MS0,1 – 2,5 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023/EPA Method 3015A rev 1Waste water/Leach waterNickel, NiICP-MS1 – 40 µg/l
Inorganic chemistrySS-EN ISO 17294-2:2023/EPA Method 3015A rev 1Waste water/Leach waterZinc, ZnICP-MS5 – 400 µg/l
SamplingSS 028185, utg 1-Drinking- and bathing water, sampling for chemical analysis--
SamplingSS 028194, utg 1-Water, sampling trace metals--
SamplingSS-EN ISO 5667–6:2016Fresh waterRivers and streams, sampling--
Water analysisHach Lange LCK 385Fresh waterTotal organic carbon, TOCPhotometry3 - 30 mg/l
Water analysisInhouse method; Odour and taste Version 3, 2022-08-09Drinking waterOdour--
Water analysisInhouse method; Odour and taste Version 3, 2022-08-09Drinking waterTaste--
Water analysisInhouse method; Odour and taste Version 3, 2022-08-09Fresh waterOdour--
Water analysisIntern metod; Analysbeskrivning extinktion 254 nm 2014-05-16Drinking waterExtinctionPhotometry0,015 – 0,7 ae/cm
Water analysisIntern metod; Analysbeskrivning extinktion 254 nm 2014-05-16Fresh waterExtinctionPhotometry0,015 – 0,7 ae/cm
Water analysisIntern metod; Transmission 254 nm, 2011-11-03Drinking waterTransmittancePhotometry39,8 – 99,0 %
Water analysisIntern metod; Transmission 254 nm, 2011-11-03Fresh waterTransmittancePhotometry39,8 – 99,0 %
Water analysisSS 028113, utg 1Drinking waterDry matterGravimetry20 – 500 mg/l
Water analysisSS 028113, utg 1Drinking waterDry matter, Residue of ignitionGravimetry20 – 500 mg/l
Water analysisSS 028113, utg 1Fresh waterDry matterGravimetry20 – 500 mg/l
Water analysisSS 028113, utg 1Fresh waterDry matter, Residue of ignitionGravimetry20 – 500 mg/l
Water analysisSS 028113, utg 1Waste water/Leach waterDry matterGravimetry20 – 500 mg/l
Water analysisSS 028113, utg 1Waste water/Leach waterDry matter, Residue of ignitionGravimetry20 – 500 mg/l
Water analysisSS 028118, utg 1Drinking waterChemical oxygen demand, COD-MnTitration1 - 10 mg/l
Water analysisSS 028118, utg 1Fresh waterChemical oxygen demand, COD-MnTitration1 - 10 mg/l
Water analysisSS 028121, utg 2Drinking waterHardness, totalTitration2 - 60 mg/l
Water analysisSS 028121, utg 2Fresh waterHardness, totalTitration2 - 60 mg/l
Water analysisSS 028125, utg 2Drinking waterTurbidityPhotometry0,05 – 100 FNU
Water analysisSS 028125, utg 2Fresh waterTurbidityPhotometry0,05 – 100 FNU
Water analysisSS 028125, utg 2Sea waterTurbidityPhotometry0,05 – 100 FNU
Water analysisSS 028125, utg 2Waste water/Leach waterTurbidityPhotometry0,05 – 100 FNU
Water analysisSS 028210, utg 1Drinking waterAluminum, AlPhotometry0,02 – 0,4 mg/l
Water analysisSS 028210, utg 1Fresh waterAluminum, AlPhotometry0,02 – 0,4 mg/l
Water analysisSS-EN 25813, utg 1Fresh waterOxygen, dissolvedTitration0,1 – 20 mg/l
Water analysisSS-EN 25813, utg 1Waste water/Leach waterOxygen, dissolvedTitration0,1 – 20 mg/l
Water analysisSS-EN 26777, utg 1Drinking waterNitrite nitrogenPhotometry1 – 150 µg/l
Water analysisSS-EN 26777, utg 1Fresh waterNitrite nitrogenPhotometry1 – 150 µg/l
Water analysisSS-EN 26777, utg 1Waste water/Leach waterNitrite nitrogenPhotometry1 – 150 µg/l
Water analysisSS-EN 27888, utg 1Drinking waterConductivityElectrode1 – 2000 mS/m
Water analysisSS-EN 27888, utg 1Fresh waterConductivityElectrode1 – 2000 mS/m
Water analysisSS-EN 27888, utg 1Sea waterConductivityElectrode1 – 2000 mS/m
Water analysisSS-EN 27888, utg 1Waste water/Leach waterConductivityElectrode1 – 2000 mS/m
Water analysisSS-EN ISO 10304-1:2009Drinking waterChlorideIon chromatography1 - 80 mg/l
Water analysisSS-EN ISO 10304-1:2009Drinking waterFluorideIon chromatography0,1 – 4 mg/l
Water analysisSS-EN ISO 10304-1:2009Drinking waterNitrate nitrogenIon chromatography100 – 1000 µg/l
Water analysisSS-EN ISO 10304-1:2009Drinking waterSulfateIon chromatography1 - 80 mg/l
Water analysisSS-EN ISO 10304-1:2009Fresh waterChlorideIon chromatography1 - 80 mg/l
Water analysisSS-EN ISO 10304-1:2009Fresh waterFluorideIon chromatography0,1 – 4 mg/l
Water analysisSS-EN ISO 10304-1:2009Fresh waterNitrate nitrogenIon chromatography100 – 1000 µg/l
Water analysisSS-EN ISO 10304-1:2009Fresh waterSulfateIon chromatography1 - 80 mg/l
Water analysisSS-EN ISO 10304-4:2022Drinking waterChlorateIon chromatography0.05-1.0 mg/l
Water analysisSS-EN ISO 10304-4:2022Drinking waterChloriteIon chromatography0.05-1.0 mg/l
Water analysisSS-EN ISO 10523:2012Drinking waterpHElectrode3 – 11
Water analysisSS-EN ISO 10523:2012Fresh waterpHElectrode3 – 11
Water analysisSS-EN ISO 10523:2012Waste water/Leach waterpHElectrode3 – 11
Water analysisSS-EN ISO 11732:2005, modDrinking waterAmmonium as nitrogenFlow analysis/Spectrometry10 – 800 µg/l
Water analysisSS-EN ISO 11732:2005, modFresh waterAmmonium as nitrogenFlow analysis/Spectrometry10 – 800 µg/l
Water analysisSS-EN ISO 11732:2005, modWaste water/Leach waterAmmonium as nitrogenFlow analysis/Spectrometry10 – 800 µg/l
Water analysisSS-EN ISO 11905-1:1998Drinking waterNitrogen, totalFlow analysis/Spectrometry80 – 2000 µg/l
Water analysisSS-EN ISO 11905-1:1998Fresh waterNitrogen, totalFlow analysis/Spectrometry80 – 2000 µg/l
Water analysisSS-EN ISO 11905-1:1998Waste water/Leach waterNitrogen, totalFlow analysis/Spectrometry80 – 2000 µg/l
Water analysisSS-EN ISO 15681-2:2018Drinking waterPhosphate phosphorousFlow analysis/Spectrometry5 – 800 µg/l
Water analysisSS-EN ISO 15681-2:2018Drinking waterPhosphorous, totalFlow analysis/Spectrometry5 – 800 µg/l
Water analysisSS-EN ISO 15681-2:2018Fresh waterPhosphate phosphorousFlow analysis/Spectrometry5 – 800 µg/l
Water analysisSS-EN ISO 15681-2:2018Fresh waterPhosphorous, totalFlow analysis/Spectrometry5 – 800 µg/l
Water analysisSS-EN ISO 15681-2:2018Waste water/Leach waterPhosphate phosphorousFlow analysis/Spectrometry5 – 800 µg/l
Water analysisSS-EN ISO 15681-2:2018Waste water/Leach waterPhosphorous, totalFlow analysis/Spectrometry5 – 800 µg/l
Water analysisSS-EN ISO 16264:2004, modDrinking waterSilicon, SiFlow analysis/Spectrometry100 – 2000 µg/l
Water analysisSS-EN ISO 16264:2004, modFresh waterSilicon, SiFlow analysis/Spectrometry100 – 2000 µg/l
Water analysisSS-EN ISO 5815-1:2019/SS-EN ISO 5814:2012Fresh waterBiochemical oxygen demand, 7 days, BOD7Electrode> 3 mg/l
Water analysisSS-EN ISO 5815-1:2019/SS-EN ISO 5814:2012Waste water/Leach waterBiochemical oxygen demand, 7 days, BOD7Electrode> 3 mg/l
Water analysisSS-EN ISO 7393-2:2018Drinking waterChlorine, totalPhotometry0,03 – 1,0 mg/l
Water analysisSS-EN ISO 7887:2012, del CDrinking waterColourPhotometry5 - 100 mg/l Pt
Water analysisSS-EN ISO 7887:2012, del CFresh waterColourPhotometry5 - 100 mg/l Pt
Water analysisSS-EN ISO 9963-2, utg 1Drinking waterAlkalinityTitration0,01 – 4 mmol/l
Water analysisSS-EN ISO 9963-2, utg 1Fresh waterAlkalinityTitration0,01 – 4 mmol/l
TeknikområdeMetod/procedurProvtyp/System/ProduktParameter/Egenskaper
SamplingSS-EN ISO 19458:2006-Water quality, sampling for microbiological analysis
Water analysisSS 028212, ed 1Drinking waterActinomycetes
Water analysisSS 028212, ed 1Fresh waterActinomycetes
Water analysisSS-EN ISO 10705-2:2000, modDrinking waterColiphages
Water analysisSS-EN ISO 10705-2:2000, modFresh waterColiphages
Water analysisSS-EN ISO 10705-2:2000, modWaste water/Leach waterColiphages
Water analysisSS-EN ISO 14189:2016Drinking waterPresumptive Clostridium perfringens
Water analysisSS-EN ISO 14189:2016Fresh waterPresumptive Clostridium perfringens
Water analysisSS-EN ISO 14189:2016Waste water/Leach waterPresumptive Clostridium perfringens
Water analysisSS-EN ISO 6222, ed 1Drinking waterTotal count of culturable micro-organisms 22°C, 3 days
Water analysisSS-EN ISO 6222, ed 1Fresh waterTotal count of culturable micro-organisms 22°C, 3 days
Water analysisSS-EN ISO 6222, ed 1Sea waterTotal count of culturable micro-organisms 22°C, 3 days
Water analysisSS-EN ISO 6222, ed 1, modDrinking waterSlowgrowing bacteria 22°C, 7 days
Water analysisSS-EN ISO 6222, ed 1, modFresh waterSlowgrowing bacteria 22°C, 7 days
Water analysisSS-EN ISO 7899-2, ed 1Drinking waterIntestinal enterococci
Water analysisSS-EN ISO 7899-2, ed 1Fresh waterIntestinal enterococci
Water analysisSS-EN ISO 7899-2, ed 1Sea waterIntestinal enterococci
Water analysisSS-EN ISO 7899-2, ed 1Waste water/Leach waterIntestinal enterococci
Water analysisSS-EN ISO 9308-2:2014Drinking waterColiform bacteria
Water analysisSS-EN ISO 9308-2:2014Drinking waterEscherichia coli
Water analysisSS-EN ISO 9308-2:2014Fresh waterColiform bacteria
Water analysisSS-EN ISO 9308-2:2014Fresh waterEscherichia coli
Water analysisSS-EN ISO 9308-2:2014Waste water/Leach waterColiform bacteria
Water analysisSS-EN ISO 9308-2:2014Waste water/Leach waterEscherichia coli