Drinking- and bathing water, sampling for chemical analysis
-
Water analysis
ISO 17289
Drinking water
Oxygen, dissolved
Optical sensor
Water analysis
ISO 17289
Fresh water
Oxygen, dissolved
Optical sensor
Water analysis
ISO 17289
Waste water/Leach water
Oxygen, dissolved
Optical sensor
Water analysis
ISO 5664
Sludges/sediments
Ammonium as nitrogen
Titration
Water analysis
SS 028136
Drinking water
Chloride
Titration
Water analysis
SS 028136
Fresh water
Chloride
Titration
Water analysis
SS 028136
Waste water/Leach water
Chloride
Titration
Water analysis
SS-EN 12879
Sludges/sediments
Residue of ignition
Gravimetry
Water analysis
SS-EN 12880
Sludges/sediments
Dry matter
Gravimetry
Water analysis
SS-EN 13342
Sludges/sediments
Nitrogen, Kjeldahl
Titration
Water analysis
SS-EN 27888
Drinking water
Conductivity
Electrode
Water analysis
SS-EN 27888
Fresh water
Conductivity
Electrode
Water analysis
SS-EN 27888
Waste water/Leach water
Conductivity
Electrode
Water analysis
SS-EN 872
Sludges/sediments
Suspended solids
Gravimetry
Water analysis
SS-EN 872
Waste water/Leach water
Suspended solids
Gravimetry
Water analysis
SS-EN ISO 10523
Drinking water
pH
Electrode
Water analysis
SS-EN ISO 10523
Fresh water
pH
Electrode
Water analysis
SS-EN ISO 10523
Sludges/sediments
pH
Electrode
Water analysis
SS-EN ISO 10523
Waste water/Leach water
pH
Electrode
Water analysis
SS-EN ISO 15923-1
Drinking water
Ammonium as nitrogen
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Drinking water
Nitrate nitrogen
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Drinking water
Nitrite nitrogen
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Drinking water
Phosphate phosphorous
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Drinking water
Sulfate
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Fresh water
Ammonium as nitrogen
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Fresh water
Nitrate nitrogen
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Fresh water
Nitrite nitrogen
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Fresh water
Phosphate phosphorous
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Fresh water
Sulfate
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Waste water/Leach water
Ammonium as nitrogen
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Waste water/Leach water
Nitrate nitrogen
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Waste water/Leach water
Nitrite nitrogen
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Waste water/Leach water
Phosphate phosphorous
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1
Waste water/Leach water
Sulfate
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1/SS-EN ISO 6878
Fresh water
Phosphorous, total
Discrete analysis/Photometry
Water analysis
SS-EN ISO 15923-1/SS-EN ISO 6878
Waste water/Leach water
Phosphorous, total
Discrete analysis/Photometry
Water analysis
SS-EN ISO 20236
Drinking water
Total organic carbon, TOC
Combustion
Water analysis
SS-EN ISO 20236
Fresh water
Nitrogen, total, TNb
Combustion
Water analysis
SS-EN ISO 20236
Fresh water
Total organic carbon, TOC
Combustion
Water analysis
SS-EN ISO 20236
Waste water/Leach water
Nitrogen, total, TNb
Combustion
Water analysis
SS-EN ISO 20236
Waste water/Leach water
Total organic carbon, TOC
Combustion
Water analysis
SS-EN ISO 5815-1/ISO 17289
Fresh water
Biochemical oxygen demand, 7 days, BOD7
Optical sensor
Water analysis
SS-EN ISO 5815-1/ISO 17289
Waste water/Leach water
Biochemical oxygen demand, 7 days, BOD7
Optical sensor
Water analysis
SS-EN ISO 7027-1
Drinking water
Turbidity
Photometry
Water analysis
SS-EN ISO 7027-1
Fresh water
Turbidity
Photometry
Water analysis
SS-EN ISO 7887, del C
Drinking water
Colour
Discrete analysis/Photometry
Water analysis
SS-EN ISO 7887, del C
Fresh water
Colour
Discrete analysis/Photometry
Water analysis
SS-EN ISO 7887, del D
Drinking water
Colour
Comparator
Water analysis
SS-EN ISO 7887, del D
Fresh water
Colour
Comparator
Water analysis
SS-EN ISO 7887, del D
Waste water/Leach water
Colour
Comparator
Water analysis
SS-EN ISO 9963-1
Sludges/sediments
Alkalinity
Titration
Water analysis
SS-EN ISO 9963-1
Waste water/Leach water
Alkalinity
Titration
Water analysis
SS-EN ISO 9963-2
Drinking water
Alkalinity
Titration
Water analysis
SS-EN ISO 9963-2
Fresh water
Alkalinity
Titration
Water analysis
SS-EN ISO 9963-2
Sludges/sediments
Alkalinity
Titration
Microbiological analysis
Technical area
Method / procedure
Parameter / Properties
Flex
Business unit
Sampling
SS-EN ISO 19458
Water quality, sampling for microbiological analysis
The accredited body has been granted flexible scope. The body shall be able to provide an updated list of the current scope of accreditation upon request.
Type 2 of flexibility:
Introduce new version of standard method and make editorial changes to non-standard method - Introduce new version and modifications of non-standard method. The procedure must be equivalent - Introduce new parameter/component/characteristics - Introduce new measurement range - Introduce new material/new products/matrices - Introduce new method equivalent to methods already in the accreditation decision
Swedacs föreskrifter och allmänna råd om ackreditering
Calibration, SS-EN ISO/IEC 17025:2018
Latest decision date: 2026-02-13
Electricity and Magnetism
Measured quantity
Method / procedure
Product / object
Parameter / Properties
Expanded measurement uncertainty ±
Measuring range / measuring level
Business unit
Resistance
Intern metod; 5244 ver 2
Heat meters
ESR
14*10⁻⁶ ohm
100 ohm – 1000 ohm
Mass related quantities
Measured quantity
Method / procedure
Product / object
Parameter / Properties
Expanded measurement uncertainty ±
Measuring range / measuring level
Remark
Business unit
Volume
Intern metod; 5249 ver 1
Volume Flow Meter
Fluid flow/Fluid velocity
0,2 %
100 – 100 000 l/h
ansl 15 – 100 mm, max 30 °C, 10 - 5000L
Volume
Intern metod; 5249 ver 1
Volume Flow Meter
Fluid flow/Fluid velocity
0,2 %
100 – 160 000 l/h
ansl 15 – 100 mm, max 65 °C, 10 - 5000L
Volume
Intern metod; 5249 ver 1
Volume Flow Meter
Fluid flow/Fluid velocity
0,3 %
6 – 100 l/h
ansl 15 – 50mm, max 30 °C, 3 - 60L
Volume
Intern metod; 5249 ver 1
Volume Flow Meter
Fluid flow/Fluid velocity
0,3 %
6 – 100 l/h
ansl 15 – 50mm, max 65 °C, 3 - 60L
Volume
Intern metod; 5249 ver 1
Water meters
Fluid flow/Fluid velocity
0,2 %
100 – 160 000 l/h
ansl 15 – 100 mm, max 65 °C, 10 - 5000L
Volume
Intern metod; 5249 ver 1
Water meters
Fluid flow/Fluid velocity
0,2%
100 – 100 000 l/h
ansl 15 – 100 mm, max 30 °C, 10 - 5000L
Volume
Intern metod; 5249 ver 1
Water meters
Fluid flow/Fluid velocity
0,3 %
6 – 100 l/h
ansl 15 – 50mm, max 30 °C, 3 - 60L
Volume
Intern metod; 5249 ver 1
Water meters
Fluid flow/Fluid velocity
0,3 %
6 – 100 l/h
ansl 15 – 50mm, max 65 °C, 3 - 60L
Temperature
Measured quantity
Method / procedure
Product / object
Expanded measurement uncertainty ±
Measuring range / measuring level
Business unit
Temperature
Intern metod; 5244 ver 2
Heat meters
0,03 °C
delta T = 20 ± 2 °C
Temperature
Intern metod; 5244 ver 2
Heat meters
0,04 °C
delta T = 30 ± 2 °C
Temperature
Intern metod; 5244 ver 2
Heat meters
0,04 °C
delta T = 50 ± 2 °C
The calibration and measurement capability (CMC) includes measureand (technology area), method, measurement range and expanded measurement uncertainty. The expanded measurement uncertainty corresponds to a coverage probability (confidence level) of ~95%.