Skip to main content

Lidköpings Carpart AB

Accreditation no: 10054

Org no:
556269-0627
Postal and visiting address:
Råda Mossevägen 4, 531 59 Lidköping · Show on map

Calibration, SS-EN ISO/IEC 17025:2018

Latest decision date: 2023-11-14

MätstorhetMetod/procedurProdukt/objektParameter/EgenskaperUtvidgad mätosäkerhet ±Utrustning/MätprincipMätområde/mätnivåAnmärkning
Air and smoke emission analysisIntern method; CARP 1.1 v5Exhaust gas analyzerCarbon dioxide, CO20,3 % volReference gas10 - 12 % Vol4 gas
Air and smoke emission analysisIntern method; CARP 1.1 v5Exhaust gas analyzerCarbon dioxide, CO20,55 % volReference gas12 - 20 % Vol4 gas
Air and smoke emission analysisIntern method; CARP 1.1 v5Exhaust gas analyzerCarbon monoxide, CO0,03 % VolReference gas1,3 - 2 % Vol4 gas
Air and smoke emission analysisIntern method; CARP 1.1 v5Exhaust gas analyzerCarbon monoxide, CO0,07 % volReference gas2 - 4 % Vol4 gas
Air and smoke emission analysisIntern method; CARP 1.1 v5Exhaust gas analyzerHC13 ppm VolReference gas250 - 500 ppm Vol4 gas
Air and smoke emission analysisIntern method; CARP 1.1 v5Exhaust gas analyzerHC22 ppm VolReference gas500 - 1000 ppm Vol4 gas
Air and smoke emission analysisIntern method; CARP 1.1 v5Exhaust gas analyzerPropan, C3H823 ppm VolReference gas500 - 1000 ppm Vol4 gas
Air and smoke emission analysisIntern method; CARP 1.1 v5Exhaust gas analyzerPropan, C3H836 ppm VolReference gas1000 - 2000 ppm Vol4 gas
MätstorhetMetod/procedurProdukt/objektUtvidgad mätosäkerhet ±Utrustning/MätprincipMätområde/mätnivåAnmärkning
AccelerationIntern method; CARP 6.1 v3Retardation meter, digital0,10 m/s2Inclined plane0 - 8 m/s2-
AccelerationIntern method; CARP 6.2 v3Retardation meter, analog0,14 m/s2Inclined plane0 - 8 m/s2-
LengthInhouse method; CARP 4.3 v3Light adjuster1.2 mm/mLaser± 0,5 %Lasermätning
LengthIntern method; CARP 4.1 v5Light adjuster1,3mm/mLamp/Slit± 0,5 %-
LengthIntern method; CARP 4.4 v3Light setting locationz = 1,1 mm, x/y = 12 mm-z = ± 100mm, x = 0 - 4000mm, y = 0 - 2500mmPersonbil
LengthIntern method; CARP 4.4 v3Light setting locationz = 1,5 mm, x/y = 12 mm-z = ± 100mm, x = 0 - 8500mm, y = 0 - 2500mmLastbil
MätstorhetMetod/procedurProdukt/objektUtvidgad mätosäkerhet ±Utrustning/MätprincipMätområde/mätnivåAnmärkning
ForceIntern method; CARP 3.1 v5Roller brake tester135 NRaise bar6201 – 10200 NLastbil
ForceIntern method; CARP 3.1 v5Roller brake tester256 NRaise bar10201 – 20200 NLastbil
ForceIntern method; CARP 3.1 v5Roller brake tester380 NRaise bar20201 – 30200 NLastbil
ForceIntern method; CARP 3.1 v5Roller brake tester52 NRaise bar900 - 1200 NPersonbil
ForceIntern method; CARP 3.1 v5Roller brake tester57 NRaise bar1201 - 2200 NPersonbil
ForceIntern method; CARP 3.1 v5Roller brake tester57 NRaise bar1900 - 2200 NLastbil
ForceIntern method; CARP 3.1 v5Roller brake tester63 NRaise bar2201 -3200 NPersonbil
ForceIntern method; CARP 3.1 v5Roller brake tester72 NRaise bar3201 N – 4200 NPersonbil
ForceIntern method; CARP 3.1 v5Roller brake tester91 NRaise bar2201 – 6200 NLastbil
ForceIntern method; CARP 3.1 v5Roller brake tester92 NRaise bar4201 – 6200 NPersonbil
ForceIntern method; CARP 3.2 v4Roller brake tester124 NPower cell6201-10200 NLastbil
ForceIntern method; CARP 3.2 v4Roller brake tester128 NPower cell4201 - 6200 NPersonbil
ForceIntern method; CARP 3.2 v4Roller brake tester160 NPower cell6201 – 8200 NPersonbil
ForceIntern method; CARP 3.2 v4Roller brake tester214 NPower cell10201-20200 NLastbil
ForceIntern method; CARP 3.2 v4Roller brake tester310 NPower cell20201-30200 NLastbil
ForceIntern method; CARP 3.2 v4Roller brake tester403 NPower cell30201-40200 NLastbil
ForceIntern method; CARP 3.2 v4Roller brake tester62 NPower cell900 – 1200 NPersonbil
ForceIntern method; CARP 3.2 v4Roller brake tester70 NPower cell1900 - 2200 NLastbil
ForceIntern method; CARP 3.2 v4Roller brake tester79 NPower cell1201- 2200 NPersonbil
ForceIntern method; CARP 3.2 v4Roller brake tester82 NPower cell2201 – 3200 NPersonbil
ForceIntern method; CARP 3.2 v4Roller brake tester93 NPower cell2201-6200 NLastbil
ForceIntern method; CARP 3.2 v4Roller brake tester95 NPower cell3201 - 4200 NPersonbil
PressureIntern method; CARP 3.3 v4Pressure gauge0,074 barReference pressure gauge1 – 20 bar-
MätstorhetMetod/procedurProdukt/objektParameter/EgenskaperUtvidgad mätosäkerhet ±Utrustning/MätprincipMätområde/mätnivåAnmärkning
Optical absorbanceIntern metod; CARP 2.1 v5Exhaust gas analyzerWave-length± 1.5 % opacityFilter glass< 100 % opacitetOpacitet
Optical absorbanceIntern metod; CARP 2.1 v5Exhaust gas analyzerWave-length0,06 m-1Filter glass0-9,99 m-1K-värde
  • The calibration and measurement capability (CMC) includes measureand (technology area), method, measurement range and expanded measurement uncertainty. The expanded measurement uncertainty corresponds to a coverage probability (confidence level) of ~95%.

Regulations

STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering