Skip to main content

Boliden Mineral AB

Accreditation no: 1011

Org no:
556231-6850
Postal address:
-, 936 31 Boliden
Business unit
Standard
Type of body

Testing, SS-EN ISO/IEC 17025:2018

Latest decision date: 2022-10-10

Technical areaMethod / procedureSample type / System / ProductParameter / PropertiesEquipment / Measurement principleFlexBusiness unit
Inorganic chemistryInhouse method: 44512Metals/Metal compoundsCarbon, CCombustion
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Drinking waterArsenic, AsICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Drinking waterCadmium, CdICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Drinking waterCopper, CuICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Drinking waterLead, PbICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Drinking waterNickel, NiICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Drinking waterZinc, ZnICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Fresh waterArsenic, AsICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Fresh waterCadmium, CdICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Fresh waterCopper, CuICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Fresh waterLead, PbICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Fresh waterNickel, NiICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Fresh waterZinc, ZnICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Sea waterArsenic, AsICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Sea waterCadmium, CdICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Sea waterCopper, CuICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Sea waterLead, PbICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Sea waterNickel, NiICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Sea waterZinc, ZnICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Waste water/Leach waterArsenic, AsICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Waste water/Leach waterCadmium, CdICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Waste water/Leach waterCopper, CuICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Waste water/Leach waterLead, PbICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Waste water/Leach waterNickel, NiICP-AES
Inorganic chemistrySS-EN ISO 11885/SS-EN ISO 15587-2Waste water/Leach waterZinc, ZnICP-AES
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Drinking waterAntimony, SbICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Drinking waterArsenic, AsICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Drinking waterCadmium, CdICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Drinking waterCobalt, CoICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Drinking waterCopper, CuICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Drinking waterLead, PbICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Drinking waterNickel, NiICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Drinking waterSilver, AgICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Drinking waterZinc, ZnICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Fresh waterAntimony, SbICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Fresh waterArsenic, AsICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Fresh waterCadmium, CdICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Fresh waterCobalt, CoICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Fresh waterCopper, CuICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Fresh waterLead, PbICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Fresh waterNickel, NiICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Fresh waterSilver, AgICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Fresh waterZinc, ZnICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Sea waterAntimony, SbICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Sea waterArsenic, AsICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Sea waterCadmium, CdICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Sea waterCobalt, CoICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Sea waterCopper, CuICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Sea waterLead, PbICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Sea waterNickel, NiICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Sea waterSilver, AgICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Sea waterZinc, ZnICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Waste water/Leach waterAntimony, SbICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Waste water/Leach waterArsenic, AsICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Waste water/Leach waterCadmium, CdICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Waste water/Leach waterCobalt, CoICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Waste water/Leach waterCopper, CuICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Waste water/Leach waterLead, PbICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Waste water/Leach waterNickel, NiICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Waste water/Leach waterSilver, AgICP-MS
Inorganic chemistrySS-EN ISO 17294-2/SS-EN ISO 15587-2Waste water/Leach waterZinc, ZnICP-MS
Inorganic chemistrySS-EN ISO 17852Drinking waterMercury, HgAFS
Inorganic chemistrySS-EN ISO 17852Fresh waterMercury, HgAFS
Inorganic chemistrySS-EN ISO 17852Sea waterMercury, HgAFS
Inorganic chemistrySS-EN ISO 17852Waste water/Leach waterMercury, HgAFS
Water analysisSS-EN 27888Drinking waterConductivityElectrode
Water analysisSS-EN 27888Fresh waterConductivityElectrode
Water analysisSS-EN 27888Sea waterConductivityElectrode
Water analysisSS-EN 27888Waste water/Leach waterConductivityElectrode
Water analysisSS-EN 872Drinking waterSuspended solidsGravimetry
Water analysisSS-EN 872Fresh waterSuspended solidsGravimetry
Water analysisSS-EN 872Sea waterSuspended solidsGravimetry
Water analysisSS-EN 872Waste water/Leach waterSuspended solidsGravimetry
Water analysisSS-EN ISO 10304-1Drinking waterChlorideIon chromatography
Water analysisSS-EN ISO 10304-1Drinking waterSulfateIon chromatography
Water analysisSS-EN ISO 10304-1Fresh waterChlorideIon chromatography
Water analysisSS-EN ISO 10304-1Fresh waterSulfateIon chromatography
Water analysisSS-EN ISO 10304-1Sea waterChlorideIon chromatography
Water analysisSS-EN ISO 10304-1Sea waterSulfateIon chromatography
Water analysisSS-EN ISO 10304-1Waste water/Leach waterChlorideIon chromatography
Water analysisSS-EN ISO 10304-1Waste water/Leach waterSulfateIon chromatography
Water analysisSS-EN ISO 10523Drinking waterpHElectrode
Water analysisSS-EN ISO 10523Fresh waterpHElectrode
Water analysisSS-EN ISO 10523Sea waterpHElectrode
Water analysisSS-EN ISO 10523Waste water/Leach waterpHElectrode
  • The accredited body has been granted flexible scope. The body shall be able to provide an updated list of the current scope of accreditation upon request.

Regulations

STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering

Inspection, SS-EN ISO/IEC 17020:2012

Latest decision date: 2021-02-25

TypeRequirements specificationType of controlPerformed in the fieldBusiness unit
CArbetsmiljöverkets föreskrifter och allmänna råd om risker vid vissa typer av arbeten. Kap 12Testing with positive or negative pressurePerformed in the field

Regulations

AFS 2023:13 Kap 12
Arbetsmiljöverkets föreskrifter och allmänna råd (AFS 2023:13) om risker vid vissa typer av arbeten. Kap 12 - Provning med över- eller undertryck
STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering