Skip to main content

Gränges Finspång AB

Accreditation no: 10190

Org no:
556002-6113
Phone:
0122-83800
Postal address:
Myrkärrsvägen 1, 612 81 Finspång
Visiting address:
Kanalgatan 1, 612 31 Finspång · Show on map

Testing, SS-EN ISO/IEC 17025:2018

Latest decision date: 2024-05-14

Technical areaMethod / procedureSample type / System / ProductParameter / PropertiesEquipment / Measurement principleMeasuring range / measuring level
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterAluminum, AlICP-AES0,1 – 100 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterCadmium, CdICP-AES0,005 – 2 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterCalcium, CaICP-AES0,05-40 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterChromium, CrICP-AES0,01 – 10 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterCopper, CuICP-AES0,01 – 20 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterIron, FeICP-AES0,01 – 20 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterMagnesium, MgICP-AES0,01 – 20 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterManganese, MnICP-AES0,01 – 10 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterNickel, NiICP-AES0,01 – 20 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Fresh waterZinc, ZnICP-AES0,01 – 20 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterAluminum, AlICP-AES0,1 – 100 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterCadmium, CdICP-AES0,005 – 2 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterCalcium, CaICP-AES0,05-40 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterChromium, CrICP-AES0,01 – 10 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterCopper, CuICP-AES0,01 – 20 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterIron, FeICP-AES0,01 – 20 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterMagnesium, MgICP-AES0,01 – 20 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterManganese, MnICP-AES0,01 – 10 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterNickel, NiICP-AES0,01 – 20 mg/l
Inorganic chemistrySS-EN ISO 11885:2009/SS 028150, utg 2Waste water/Leach waterZinc, ZnICP-AES0,01 – 20 mg/l
Water analysisASTM D516-82, modFresh waterSulfateGravimetry2 – 5000 mg/l
Water analysisASTM D516-82, modWaste water/Leach waterSulfateGravimetry2 – 5000 mg/l
Water analysisSS 028135, utg 1, modFresh waterFluorideIon selective electrode0,25 – 190 mg/l
Water analysisSS 028135, utg 1, modWaste water/Leach waterFluorideIon selective electrode0,25 – 190 mg/l
Water analysisSS 028136, utg 1, modFresh waterChlorideTitration2 – 100 mg/l
Water analysisSS 028136, utg 1, modWaste water/Leach waterChlorideTitration2 – 100 mg/l
Water analysisSS-EN 27888, utg 1, modFresh waterConductivityElectrode0,1 – 300 mS/m
Water analysisSS-EN 27888, utg 1, modWaste water/Leach waterConductivityElectrode0,1 – 300 mS/m
Water analysisSS-EN 872:2005, modWaste water/Leach waterSuspended solidsGravimetry> 5 mg/l
Water analysisSS-EN ISO 10523:2012Fresh waterpHElectrode3 – 10
Water analysisSS-EN ISO 10523:2012Waste water/Leach waterpHElectrode3 – 10

Regulations

STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering