Carlann AB
Accreditation no: 10481
- Postal address:
- Vivelvägen 8, 184 34 Åkersberga
- Visiting address:
- Sågvägen 19, 184 40 Åkersberga · Show on map
Calibration, SS-EN ISO/IEC 17025:2018
Latest decision date: 2025-07-03
| Mätstorhet | Metod/procedur | Produkt/objekt | Utvidgad mätosäkerhet ± | Mätområde/mätnivå |
|---|---|---|---|---|
| Length | ASTM E83-23 | Beam, piston movement | 0,03 % | 5 – 1000 mm |
| Length | ASTM E83-23 | Elongation gauge | 0,06 % | 0,01 – 50 mm |
| Length | ASTM E83-23 | Extensometer | 0,06 % | 0,01 – 50 mm |
| Length | SS-EN ISO 9513:2012/AC:2013 | Beam, piston movement | 0,03 % | 5 – 1000 mm |
| Length | SS-EN ISO 9513:2012/AC:2013 | Elongation gauge | 0,06 % | 0,01 – 50 mm |
| Length | SS-EN ISO 9513:2012/AC:2013 | Extensometer | 0,06 % | 0,01 – 50 mm |
| Mätstorhet | Metod/procedur | Produkt/objekt | Parameter/Egenskaper | Utvidgad mätosäkerhet ± | Utrustning/Mätprincip | Mätområde/mätnivå | Anmärkning |
|---|---|---|---|---|---|---|---|
| Force | ASTM E4-24 | Fatigue machine | - | 0,01 % | - | 0,005 – 600 kN | - |
| Force | ASTM E4-24 | Spring testing machine | - | 0,01 % | - | 0,005 – 600 kN | - |
| Force | ASTM E4-24 | Tensile testing machine | - | 0,01 % | - | 0,005 – 600 kN | - |
| Force | DynamoMeter JK Lab Service, edition 1 | Force measuring device | - | 0,1 % | - | 0,005 – 600 kN | Bygger på SS-EN ISO 7500-1:2004 |
| Force | SS-EN ISO 7500-1:2018 | Fatigue machine | - | 0,1 % | - | 0,005 – 600 kN | - |
| Force | SS-EN ISO 7500-1:2018 | Spring testing machine | - | 0,1 % | - | 0,005 – 600 kN | - |
| Force | SS-EN ISO 7500-1:2018 | Tensile testing machine | - | 0,1 % | - | 0,005 – 600 kN | - |
| Hardness | ASTM E10-23 | Hardness meter | Brinell, vickers etc | 1,0 % | Brinell | 3 – 650 HB | Avsnitt 4.3.4.1 samt 4.3.4.2 undantagna. |
| Hardness | ASTM E18-24 | Hardness meter | Brinell, vickers etc | 0,5% | Rockwell | Skalorna: A – H, K, N, T | Avsnitt 4.3.1.1.2 - 4.3.1.1.5 samt 4.3.2. undantagna. |
| Hardness | ASTM E92:2023 | Hardness meter | Brinell, vickers etc | 1,0 % | Vickers | HV 0,1 – 100 | Avsnitt 4.3.2 – 4.3.4 undantagna. |
| Hardness | SS-EN ISO 6506-2:2019 | Hardness meter | Brinell, vickers etc | 1,0 % | Brinell | 3 – 650 HB | Avsnitt 4.3.4.1 samt 4.3.4.2 undantagna. |
| Hardness | SS-EN ISO 6507-2:2018 | Hardness meter | Brinell, vickers etc | 1,0 % | Vickers | HV 0,1 – 100 | Avsnitt 4.3.2 – 4.3.4 undantagna. |
| Hardness | SS-EN ISO 6508-2:2024 | Hardness meter | Brinell, vickers etc | 0,5% | Rockwell | Skalorna: A – H, K, N, T | Avsnitt 4.3.1.1.2 - 4.3.1.1.5 samt 4.3.2. undantagna. |
| Impact testing | SS-EN ISO 148-2:2016 | Impact testing machine | - | 0,9-5,0 J | Indirectly | 15 – 250 J | Avsnitt 6.3.2 – 6.3.10, 6.4.2 – 6.4.4, 6.4.6 samt 6.4.8 undantagna. |
- The calibration and measurement capability (CMC) includes measureand (technology area), method, measurement range and expanded measurement uncertainty. The expanded measurement uncertainty corresponds to a coverage probability (confidence level) of ~95%.
Regulations
- STAFS 2020:1
- Swedacs föreskrifter och allmänna råd om ackreditering