Skip to main content

Magna Electronics Sweden AB

Accreditation no: 10601

Postal address:
Teknikringen 5, 583 30 Linköping
Visiting address:
Datalinjen 3C, 583 30 Linköping · Show on map

Testing, SS-EN ISO/IEC 17025:2018

Latest decision date: 2026-06-23

Technical areaMethod / procedureSample type / System / ProductParameter / PropertiesMeasuring range / measuring levelRemark
EMCCISPR 25: 2021Vehicle componentsConducted emission – Current100 kHz - 400 MHzOnly components and modules
EMCCISPR 25: 2021Vehicle componentsConducted emission – Voltage100 kHz - 150 MHzOnly components and modules
EMCCISPR 25: 2021Vehicle componentsEmission150 kHz - 6000 MHzOnly components and modules
EMCCISPR 25: 2021Vehicle componentsStripline150 kHz - 960 MHzOnly components and modules
EMCISO 10605: 2008+Cor1:2010+Amd1:2014Vehicle componentsESDAir: ± (2 - 25) kVOnly components and modules
EMCISO 10605: 2008+Cor1:2010+Amd1:2014Vehicle componentsESDContact: ± (2 - 15) kVOnly components and modules
EMCISO 10605:2023Vehicle componentsESDAir: ± (2 - 25) kVOnly components and modules
EMCISO 10605:2023Vehicle componentsESDContact: ± (2 - 15) kVOnly components and modules
EMCISO 7637-2:2011Vehicle componentsTransient immunity(12 - 24) V DCTest pulse 1, 2a, 2b, 3a och 3b

Regulations

STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering