Skip to main content

Mondi Dynäs Aktiebolag

Accreditation no: 1166

Org no:
556114-9138
Phone:
0612-83000
Postal address:
-,, 873 81 Väja
Visiting address:
Dynäs, 873 81 Väja · Show on map

Testing, SS-EN ISO/IEC 17025:2018

Latest decision date: 2024-04-02

TeknikområdeMetod/procedurProvtyp/System/ProduktParameter/EgenskaperUtrustning/MätprincipMätområde/mätnivå
Water analysisHach Lange LCK 349Waste water/Leach waterPhosphorous, totalPhotometry0,15 – 4,5 mg/l
Water analysisHach Lange LCK 814Waste water/Leach waterChemical oxygen demand, COD-CrPhotometry30 – 1000 mg/l
Water analysisSS-EN 872:2005Waste water/Leach waterSuspended solidsGravimetry> 2 mg/l
Water analysisSS-EN ISO 10523:2012Waste water/Leach waterpHElectrode3 – 10
Water analysisSS-EN ISO 20236:2021Waste water/Leach waterNitrogen, total, TNbCombustion0,3 - 50 mg/l
Water analysisSS-EN ISO 20236:2021Waste water/Leach waterTotal organic carbon, TOCCombustion10 – 400 mg/l

Regulations

ILAC G17:01/2021
ILAC Guidelines for Measurement Uncertainty in Testing
STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering