Skip to main content

Metlab Miljö Aktiebolag

Accreditation no: 1288

Org no:
556067-7311
Website:
www.metlab.se
Postal and visiting address:
Fjärdhundragatan 68, 745 31 Enköping · Show on map
Business unit
Type of body

Testing, SS-EN ISO/IEC 17025:2018

Latest decision date: 2026-08-05

Technical areaMethod / procedureSample type / System / ProductParameter / PropertiesEquipment / Measurement principleFlexStatusBusiness unit
Air and smoke emission analysisEnergiforsk Emissionsmäthandbok 2015, kap 5.29Stationary source emissionsTemperatureThermocouple
Air and smoke emission analysisIntern metod för CO, N2O, TOC, HCl, HF, NH3, Hg, SO2, fukt, tempStationary source emissionsComparison measurement of fixed flue gas systemsCalculation
Air and smoke emission analysisNaturvårdsverket Informationsblad: Beräkning av rökgasflöden, Kväveoxidavgiften dec 2006Stationary source emissionsFlue gas flowCalculation
Air and smoke emission analysisNFS 2016:13Stationary source emissionsComparison measurement of fixed flue gas systemsCalculation
Air and smoke emission analysisSS 028425Stationary source emissionsNitric oxide, NO/NoxIR
Air and smoke emission analysisSS 028425Stationary source emissionsNitric oxide, NO/NoxUV
Air and smoke emission analysisSS 028425Stationary source emissionsNitrogen dioxide, NO2UV
Air and smoke emission analysisSS 028427Stationary source emissionsHydrocarbon compounds, gaseousFID
Air and smoke emission analysisSS-EN 12619Process gasesTotal organic carbon, TOCFID
Air and smoke emission analysisSS-EN 12619Stationary source emissionsTotal organic carbon, TOCFID
Air and smoke emission analysisSS-EN 13284-1Stationary source emissionsStuff contentGravimetry
Air and smoke emission analysisSS-EN 13284-2Stationary source emissionsCalibration function for AMS at QAL2Calculation
Air and smoke emission analysisSS-EN 13284-2Stationary source emissionsCalibration function, extended for AMS, at ASTCalculation
Air and smoke emission analysisSS-EN 14181Stationary source emissionsCalibration function for AMS at QAL2Calculation
Air and smoke emission analysisSS-EN 14181Stationary source emissionsCalibration function, extended for AMS, at ASTCalculation
Air and smoke emission analysisSS-EN 14789Stationary source emissionsOxygen, O2Paramagnetic
Air and smoke emission analysisSS-EN 14790Stationary source emissionsMoisture content, water vaporGravimetry
Air and smoke emission analysisSS-EN 14792Stationary source emissionsNitric oxide, NO/NoxChemiluminescence/converter
Air and smoke emission analysisSS-EN 14792Stationary source emissionsNitrogen dioxide, NO2Chemiluminescence calculation
Air and smoke emission analysisSS-EN 15058Stationary source emissionsCarbon monoxide, COIR
Air and smoke emission analysisSS-EN 15058:2017Stationary source emissionsCarbon monoxide, COIR
Air and smoke emission analysisSS-EN ISO 16911-1Stationary source emissionsGas velocity/Gas flowHolding tube
Air and smoke emission analysisSS-EN ISO 16911-2Stationary source emissionsCalibration function for AMS at QAL2Calculation
Air and smoke emission analysisSS-EN ISO 16911-2Stationary source emissionsCalibration function, extended for AMS, at ASTCalculation
Air and smoke emission analysisSS-EN ISO 21258Stationary source emissionsLuaghing gas, N2OIR
Air and smoke emission analysisSS-EN ISO 25140Stationary source emissionsMethane, CH4FID
Air and smoke emission analysisSS-EN ISO 25140Stationary source emissionsNon-methane hydrocarbons (NMHC)Calculation
Air and smoke emission analysisSS-ISO 10780Stationary source emissionsGas velocity/Gas flowHolding tube
Air and smoke emission analysisSS-ISO 10780Stationary source emissionsPressureDifferential pressure gauge
Air and smoke emission analysisSS-ISO 12039Stationary source emissionsCarbon dioxide, CO2IR
Air and smoke emission analysisSS-ISO 12039Stationary source emissionsOxygen, O2Electrochemical cell
Air and smoke emission analysisSS-ISO 12039Stationary source emissionsOxygen, O2Zirconium Oxide Cell
Air and smoke emission analysisSS-ISO 7935Stationary source emissionsSulfur dioxide, SO2IR
Air and smoke emission analysisSS-ISO 7935Stationary source emissionsSulfur dioxide, SO2UV
SamplingEnergiforsk Emissionsmäthandbok 2015, kap 5.14Stationary source emissionsSulfur trioxide, SO3Wet chemical
SamplingEnergiforsk Emissionsmäthandbok 2015, kap 5.16Stationary source emissionsHydrogen cyanide, HCNWet chemical
SamplingSIS-CEN/TS 17340Stationary source emissionsHydrogen fluoride, HFWet chemical
SamplingSS 028427Stationary source emissionsHydrocarbon aerosolsFilter
SamplingSS-EN 13211Stationary source emissionsMercury, total, HgWet chemical
SamplingSS-EN 14385Stationary source emissionsMetal elements, totalWet chemical
SamplingSS-EN 14791Stationary source emissionsSulfur dioxide, SO2Wet chemical
SamplingSS-EN 1911Stationary source emissionsHydrochloric acid, HClWet chemical
SamplingSS-EN 1911, modStationary source emissionsHydrogen bromide, HBrWet chemical
SamplingSS-EN 1948-1Stationary source emissionsDioxins, PCDD/PCDFFilter/cooling
SamplingSS-EN 1948-1, modStationary source emissionsChlorinated benzenesFilter/cooling
SamplingSS-EN 1948-1, modStationary source emissionsChlorinated phenolsFilter/cooling
SamplingSS-EN 1948-4Stationary source emissionsPCBFilter/cooling
SamplingSS-EN ISO 13833Stationary source emissionsCarbon dioxide biogenic/fossilConstant-flow sampling gas wash bottle, gas sample bag
SamplingSS-EN ISO 13833Stationary source emissionsCarbon dioxide biogenic/fossilProportional-flow sampling gas wash bottle, gas sample bag
SamplingSS-EN ISO 21877Stationary source emissionsAmmonia, NH3Wet chemical
SamplingSS-ISO 11338-1Stationary source emissionsPAHFilter/cooling
SamplingSS-ISO 15713Stationary source emissionsHydrogen fluoride, HFWet chemical
SamplingVDI 3486-2Stationary source emissionsHydrogen sulfideWet chemical
  • The accredited body has been granted flexible scope. The body shall be able to provide an updated list of the current scope of accreditation upon request.

Regulations

NFS 2016:13
Naturvårdsverkets föreskrifter om mätutrustning för bestämmande av miljöavgift på utsläpp av kväveoxider vid energiproduktion
STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering

Calibration, SS-EN ISO/IEC 17025:2018

Latest decision date: 2026-08-05

Measured quantityMethod / procedureProduct / objectParameter / PropertiesExpanded measurement uncertainty ±Equipment / Measurement principleMeasuring range / measuring levelFlexBusiness unit
SpeedIntern metod; METLAB: C10Stationary source emissionsGas flow1,1 %Holding tube5 - 35 m/s
Measured quantityMethod / procedureProduct / objectParameter / PropertiesExpanded measurement uncertainty ±Measuring range / measuring levelFlexBusiness unit
FlowInhouse method; METLAB: C7Gas flow meterGas flow1,2 %1 - 140 l/min
  • The calibration and measurement capability (CMC) includes measureand (technology area), method, measurement range and expanded measurement uncertainty. The expanded measurement uncertainty corresponds to a coverage probability (confidence level) of ~95%.
  • The accredited body has been granted flexible scope. The body shall be able to provide an updated list of the current scope of accreditation upon request.

Regulations

STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering