Calibration, SS-EN ISO/IEC 17025:2018

Latest decision date: 2021-06-03

MätstorhetMetod/procedurProdukt/objektUtvidgad mätosäkerhet ±Utrustning/MätprincipMätområde/mätnivå
LengthMetod 1.2.1 utg 12Surface plate0,8 µmLaser interferometer300 x 300 mm
LengthMetod 1.2.1 utg 12Surface plate1,0 µmLaser interferometer1000 x 1000 mm
LengthMetod 1.2.1 utg 12Surface plate1,5 µmLaser interferometer2000 x 2000 mm
LengthMetod 1.2.1 utg 12Surface plate2,1 µmLaser interferometer3500 x 3500 mm
LengthMetod 1.3 utg 12Measuring benches1,1 + 1,2L µmLaser measurement0-20 m
  • The calibration and measurement capability (CMC) includes measureand (technology area), method, measurement range and expanded measurement uncertainty. The expanded measurement uncertainty corresponds to a coverage probability (confidence level) of ~95%.

Regulations

STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering