Skip to main content

JB Maskinteknik AB

Accreditation no: 1898

Postal and visiting address:
Bäckstensgatan 9, 431 49 Mölndal · Show on map

Calibration, SS-EN ISO/IEC 17025:2018

Latest decision date: 2022-11-23

Measured quantityMethod / procedureProduct / objectParameter / PropertiesExpanded measurement uncertainty ±Equipment / Measurement principleMeasuring range / measuring levelPerformed in the field
Air and smoke emission analysisInhouse method; 4.1.3 Ed 2Exhaust gas analyzerCarbon dioxide, CO20,32 % volReference gas0,30 - 16% (vol)Performed in the field
Air and smoke emission analysisInhouse method; 4.1.3 Ed 2Exhaust gas analyzerCarbon monoxide, CO0,08 % volReference gas1,0 - 3,7 % (vol)Performed in the field
Air and smoke emission analysisInhouse method; 4.1.3 Ed 2Exhaust gas analyzerPropan, C3H842 ppm, volReference gas42 - 2130 ppm(vol)Performed in the field
Measured quantityMethod / procedureProduct / objectExpanded measurement uncertainty ±Measuring range / measuring levelRemarkPerformed in the field
AccelerationInhouse method; 4.1.7 Ed 2Retardation meter, analog0,13 m/s²2 - 7,4 m/s²-Performed in the field
AccelerationInhouse method; 4.1.7 Ed 2Retardation meter, analog1,3 %G1,3 %G20 - 75%G-Performed in the field
AccelerationInhouse method; 4.1.7 Ed 2Retardation meter, digital0,16 m/s²2 - 7,4 m/s²-Performed in the field
AccelerationInhouse method; 4.1.7 Ed 2Retardation meter, digital1,6 %G20 - 75%G-Performed in the field
LengthInhouse method; 4.1.6 Ed 3Light setting Unit1,0 mm/m, 0,10% downward angleX=5,70±0,75 mLastvagnPerformed in the field
LengthInhouse method; 4.1.6 Ed 3Light setting Unit1,4 mm/m, 0,14% downward angle1 - 4% nedvinkling-Performed in the field
LengthInhouse method; 4.1.6 Ed 3Light setting Unit1,6 mm/m, 0,16% downward angleX=3,20±0,75 mPersonvagnPerformed in the field
LengthInhouse method; 4.1.6 Ed 3Light setting Unit3,0 mm/m, 0,30% downward angleX=2,20±0,75 mMotorcykelPerformed in the field
Measured quantityMethod / procedureProduct / objectExpanded measurement uncertainty ±Measuring range / measuring levelPerformed in the field
ForceInhouse method; 4.1.5 Ed 5Roller brake tester127 N5 001 - 20 000 NPerformed in the field
ForceInhouse method; 4.1.5 Ed 5Roller brake tester209 N20 001 - 40 000 NPerformed in the field
ForceInhouse method; 4.1.5 Ed 5Roller brake tester84 N1 - 5 000 NPerformed in the field
PressureInhouse method; 4.1.2 Ed 4Pressure gauge0,030 bar1 - 35 barPerformed in the field
Measured quantityMethod / procedureProduct / objectParameter / PropertiesExpanded measurement uncertainty ±Equipment / Measurement principleMeasuring range / measuring levelPerformed in the field
Optical absorbanceInhouse method; 4.1.4 Ed 2Diesel test instrumentOptical absorbance, wavelength2,1 % opacitetReference filter< 100% opacitetPerformed in the field
  • The calibration and measurement capability (CMC) includes measureand (technology area), method, measurement range and expanded measurement uncertainty. The expanded measurement uncertainty corresponds to a coverage probability (confidence level) of ~95%.

Regulations

STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering