| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Aluminum, Al | ICP-MS | 0,005 - 2 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Antimony, Sb | ICP-MS | 0,5 - 10 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Arsenic, As | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Boron, B | ICP-MS | 15 - 150 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Cadmium, Cd | ICP-MS | 0,15 - 10 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Calcium, Ca | ICP-MS | 1 - 400 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Chromium, Cr | ICP-MS | 5 - 100 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Copper, Cu | ICP-MS | 0,005 - 2 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Hardness, total | Calculation | >/= 0,5°dH | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Iron, Fe | ICP-MS | 0,005 - 2 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Lead, Pb | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Magnesium, Mg | ICP-MS | 0,5 - 120 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Manganese, Mn | ICP-MS | 0,002 - 2 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Mercury, Hg | ICP-MS | 0,05 - 1 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Nickel, Ni | ICP-MS | 2 - 40 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Potassium, K | ICP-MS | 0,5 - 40 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Selenium, Se | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Silicon, Si | ICP-MS | 1 - 7,5 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Sodium, Na | ICP-MS | 2 - 400 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Drinking water | Uranium, U | ICP-MS | 0,001 - 0,4 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Aluminum, Al | ICP-MS | 0,005 - 2 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Antimony, Sb | ICP-MS | 0,5 - 10 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Arsenic, As | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Boron, B | ICP-MS | 15 - 150 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Cadmium, Cd | ICP-MS | 0,15 - 10 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Calcium, Ca | ICP-MS | 1 - 400 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Chromium, Cr | ICP-MS | 5 - 100 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Copper, Cu | ICP-MS | 0,005 - 2 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Hardness, total | Calculation | >/= 0,5°dH | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Iron, Fe | ICP-MS | 0,005 - 2 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Lead, Pb | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Magnesium, Mg | ICP-MS | 0,5 - 120 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Manganese, Mn | ICP-MS | 0,002 - 2 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Mercury, Hg | ICP-MS | 0,05 - 1 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Nickel, Ni | ICP-MS | 2 - 40 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Potassium, K | ICP-MS | 0,5 - 40 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Selenium, Se | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Silicon, Si | ICP-MS | 1 - 7,5 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Sodium, Na | ICP-MS | 2 - 400 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Fresh water | Uranium, U | ICP-MS | 0,001 - 0,4 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023 | Waste water/Leach water | Iron, Fe | ICP-MS | 0,005 - 2 mg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Aluminum, Al | ICP-MS | 0,05 - 2 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Antimony, Sb | ICP-MS | 0,5 - 10 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Arsenic, As | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Boron, B | ICP-MS | 30-150 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Cadmium, Cd | ICP-MS | 0,15 - 10 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Calcium, Ca | ICP-MS | 5 - 400 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Chromium, Cr | ICP-MS | 5 - 100 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Copper, Cu | ICP-MS | 0,02 - 2 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Iron, Fe | ICP-MS | 0,03 - 2 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Lead, Pb | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Magnesium, Mg | ICP-MS | 2 - 120 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Manganese, Mn | ICP-MS | 0,01 - 2 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Nickel, Ni | ICP-MS | 2 - 40 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Potassium, K | ICP-MS | 1 - 40 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Selenium, Se | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Sodium, Na | ICP-MS | 5 - 400 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Drinking water | Uranium, U | ICP-MS | 0,001 - 0,4 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Aluminum, Al | ICP-MS | 0,05 - 2 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Antimony, Sb | ICP-MS | 0,5 - 10 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Arsenic, As | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Boron, B | ICP-MS | 30-150 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Cadmium, Cd | ICP-MS | 0,15 - 10 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Calcium, Ca | ICP-MS | 5 - 400 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Chromium, Cr | ICP-MS | 5 - 100 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Copper, Cu | ICP-MS | 0,02 - 2 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Iron, Fe | ICP-MS | 0,03 - 2 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Lead, Pb | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Magnesium, Mg | ICP-MS | 2 - 120 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Manganese, Mn | ICP-MS | 0,01 - 2 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Nickel, Ni | ICP-MS | 2 - 40 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Potassium, K | ICP-MS | 1 - 40 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Selenium, Se | ICP-MS | 1 - 20 µg/l | - |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Sodium, Na | ICP-MS | 5 - 400 mg/l | med uppslutning |
| Inorganic chemistry | SS-EN ISO 17294-2:2023/SS-EN ISO 15587-2:2002 | Fresh water | Uranium, U | ICP-MS | 0,001 - 0,4 mg/l | med uppslutning |
| Water analysis | Inhouse method; Odor and taste in drinking water, ed. 1.0 | Drinking water | Odour | - | - | - |
| Water analysis | Inhouse method; Odor and taste in drinking water, ed. 1.0 | Drinking water | Taste | - | - | - |
| Water analysis | Inhouse method; Odor and taste in drinking water, ed. 1.0 | Fresh water | Odour | - | - | - |
| Water analysis | Inhouse method; Odor and taste in drinking water, ed. 1.0 | Fresh water | Taste | - | - | - |
| Water analysis | ISO 7027-1: 2016 | Drinking water | Turbidity | Photometry | 0,1-200 FNU | - |
| Water analysis | ISO 7027-1: 2016 | Fresh water | Turbidity | Photometry | 0,1-200 FNU | - |
| Water analysis | SS 028113, utg 1 | Sludges/sediments | Residue of ignition | Gravimetry | > 20 mg/l | - |
| Water analysis | SS 028118, utg 1 | Drinking water | Chemical oxygen demand, COD-Mn | Titration | 1 - 10 mg/l | - |
| Water analysis | SS 028118, utg 1 | Fresh water | Chemical oxygen demand, COD-Mn | Titration | 1 - 10 mg/l | - |
| Water analysis | SS-EN 12880:2000 | Sludges/sediments | Dry matter | Gravimetry | > 20 mg/l | - |
| Water analysis | SS-EN 1484, utg 1 | Drinking water | Total organic carbon, TOC | Combustion | 1,5 - 500 mg/l | - |
| Water analysis | SS-EN 1484, utg 1 | Fresh water | Total organic carbon, TOC | Combustion | 1,5 - 500 mg/l | - |
| Water analysis | SS-EN 1484, utg 1 | Waste water/Leach water | Total organic carbon, TOC | Combustion | 1,5 - 500 mg/l | - |
| Water analysis | SS-EN 16169:2012 | Sludges/sediments | Nitrogen, Kjeldahl | Kjeldahl titration | > 12,5 mg/kg TS | - |
| Water analysis | SS-EN 16169:2012 | Sludges/sediments | Nitrogen, Kjeldahl | Kjeldahl titration | > 12,5 mg/kg TS | Utan uppslutning, NH4-N |
| Water analysis | SS-EN 27888, utg 1 | Drinking water | Conductivity | Electrode | 2 - 700 mS/m | - |
| Water analysis | SS-EN 27888, utg 1 | Fresh water | Conductivity | Electrode | 2 - 700 mS/m | - |
| Water analysis | SS-EN 27888, utg 1 | Waste water/Leach water | Conductivity | Electrode | 2 - 700 mS/m | - |
| Water analysis | SS-EN 872:2005 | Fresh water | Suspended solids | Gravimetry | > 5 mg/l | - |
| Water analysis | SS-EN 872:2005 | Waste water/Leach water | Suspended solids | Gravimetry | > 5 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Drinking water | Chloride | Ion chromatography | 5 - 100 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Drinking water | Fluoride | Ion chromatography | 0,1 – 2 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Drinking water | Nitate | Ion chromatography | 2 - 30 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Drinking water | Sulfate | Ion chromatography | 3 - 100 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Fresh water | Chloride | Ion chromatography | 5 - 100 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Fresh water | Fluoride | Ion chromatography | 0,1 – 2 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Fresh water | Nitate | Ion chromatography | 2 - 30 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Fresh water | Sulfate | Ion chromatography | 3 - 100 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Waste water/Leach water | Chloride | Ion chromatography | 5 - 100 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Waste water/Leach water | Fluoride | Ion chromatography | 0,1 – 2 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Waste water/Leach water | Nitate | Ion chromatography | 2 - 30 mg/l | - |
| Water analysis | SS-EN ISO 10304-1:2009 | Waste water/Leach water | Sulfate | Ion chromatography | 3 - 100 mg/l | - |
| Water analysis | SS-EN ISO 10390:2022 | Sludges/sediments | pH | Electrode | 3 – 10 | - |
| Water analysis | SS-EN ISO 10523:2012 | Drinking water | pH | Electrode | 4 – 11 | - |
| Water analysis | SS-EN ISO 10523:2012 | Fresh water | pH | Electrode | 4 – 11 | - |
| Water analysis | SS-EN ISO 10523:2012 | Waste water/Leach water | pH | Electrode | 4 – 11 | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Drinking water | Ammonium as nitrogen | Discrete analysis/Photometry | 0,05 - 0,5 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Drinking water | Nitrite nitrogen | Discrete analysis/Photometry | 0,003 - 0,1 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Drinking water | Phosphate phosphorous | Discrete analysis/Photometry | 0,02 - 0,5 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Fresh water | Ammonium as nitrogen | Discrete analysis/Photometry | 0,05 - 0,5 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Fresh water | Nitrite nitrogen | Discrete analysis/Photometry | 0,003 - 0,1 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Fresh water | Phosphate phosphorous | Discrete analysis/Photometry | 0,02 - 0,5 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Waste water/Leach water | Ammonium as nitrogen | Discrete analysis/Photometry | 0,05 - 0,5 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Waste water/Leach water | Nitrite nitrogen | Discrete analysis/Photometry | 0,003 - 0,1 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Waste water/Leach water | Nitrite nitrogen and nitrate nitrogen | Discrete analysis/Photometry | 0,5 – 5 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024 | Waste water/Leach water | Phosphate phosphorous | Discrete analysis/Photometry | 0,02 - 0,5 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024/SS-EN ISO 6878:2005 | Fresh water | Phosphorous, total | Discrete analysis/Photometry | 0,02 – 1 mg/l | - |
| Water analysis | SS-EN ISO 15923-1:2024/SS-EN ISO 6878:2005 | Waste water/Leach water | Phosphorous, total | Discrete analysis/Photometry | 0,02 – 1 mg/l | - |
| Water analysis | SS-EN ISO 20236:2021 | Fresh water | Nitrogen, total | Combustion | 1 - 100 mg/l | - |
| Water analysis | SS-EN ISO 20236:2021 | Waste water/Leach water | Nitrogen, total | Combustion | 1 - 100 mg/l | - |
| Water analysis | SS-EN ISO 5815-1:2019/ISO 17289:2014 | Fresh water | Biochemical oxygen demand, 7 days, BOD7 | Optical sensor | > 3 mg/l | - |
| Water analysis | SS-EN ISO 5815-1:2019/ISO 17289:2014 | Waste water/Leach water | Biochemical oxygen demand, 7 days, BOD7 | Optical sensor | > 3 mg/l | - |
| Water analysis | SS-EN ISO 7887:2012, del D | Drinking water | Colour | - | 5 – 70 mg/l Pt | - |
| Water analysis | SS-EN ISO 7887:2012, del D | Fresh water | Colour | - | 5 – 70 mg/l Pt | - |
| Water analysis | SS-EN ISO 9963-2, utg 1 | Drinking water | Alkalinity | Titration | 15 - 500 mg/l | - |
| Water analysis | SS-EN ISO 9963-2, utg 1 | Fresh water | Alkalinity | Titration | 15 - 500 mg/l | - |
| Water analysis | SS-EN ISO 9963-2, utg 1 | Waste water/Leach water | Alkalinity | Titration | 15 - 500 mg/l | - |