Skip to main content

Veolia Water Technologies AB

Accreditation no: 2031

Org no:
556273-8582
Phone:
046-182150
Postal and visiting address:
Klosterängsvägen 11A, 226 47 Lund · Show on map

Testing, SS-EN ISO/IEC 17025:2018

Latest decision date: 2026-02-26

TeknikområdeMetod/procedurProvtyp/System/ProduktParameter/EgenskaperMätområde/mätnivå
Water analysisNaturvårdsverkets rapport 4424ChemicalsNitrification inhibition0 – 100 %
Water analysisNaturvårdsverkets rapport 4424Waste water/Leach waterNitrification inhibition0 – 100 %
Water analysisSS-EN ISO 7827:2012/OECD 301 AChemicalsBiological degradation0 – 100 %
Water analysisSS-EN ISO 7827:2012/OECD 301 AWaste water/Leach waterBiological degradation0 – 100 %
Water analysisSS-EN ISO 8192:2007ChemicalsRespiratory depression0 – 100 %
Water analysisSS-EN ISO 8192:2007Waste water/Leach waterRespiratory depression0 – 100 %
Water analysisSS-EN ISO 9408:2000/OECD 301 FChemicalsBiological degradation0 – 100 %
Water analysisSS-EN ISO 9408:2000/OECD 301 FWaste water/Leach waterBiological degradation0 – 100 %
Water analysisSS-EN ISO 9509: 2006ChemicalsNitrification inhibition0 – 100 %
Water analysisSS-EN ISO 9509: 2006Waste water/Leach waterNitrification inhibition0 – 100 %
Water analysisSS-EN ISO 9888: 1999/OECD 302 BChemicalsBiological degradation0 – 100 %
Water analysisSS-EN ISO 9888: 1999/OECD 302 BWaste water/Leach waterBiological degradation0 – 100 %
TeknikområdeMetod/procedurProvtyp/System/ProduktParameter/EgenskaperUtrustning/MätprincipMätområde/mätnivå
Water analysisHach Lange LCI 400ChemicalsChemical oxygen demand, COD-CrPhotometry30-1000 mg/l
Water analysisHach Lange LCI 400Waste water/Leach waterChemical oxygen demand, COD-CrPhotometry30-1000 mg/l
Water analysisHach Lange LCK 138Waste water/Leach waterNitrogen, totalPhotometry1,2 – 16 mg/l
Water analysisHach Lange LCK 349Waste water/Leach waterPhosphorous, totalPhotometry0,05 – 1,5 mg/l
Water analysisHach Lange LCK 350Waste water/Leach waterPhosphorous, totalPhotometry2 – 20 mg/l
Water analysisISO 15923-1:2013-Nitrate nitrogenCalculation-
Water analysisISO 15923-1:2013Waste water/Leach waterAmmonium as nitrogenDiscrete analysis/Photometry0,4 – 4,0 mg/l
Water analysisISO 15923-1:2013Waste water/Leach waterNitrite nitrogenDiscrete analysis/Photometry0,5 – 5,0 mg/l
Water analysisISO 15923-1:2013Waste water/Leach waterNitrite nitrogen and nitrate nitrogenDiscrete analysis/Photometry0,5 – 5,0 mg/l
Water analysisISO 15923-1:2013Waste water/Leach waterPhosphate phosphorousDiscrete analysis/Photometry0,2 – 2,0 mg/l
Water analysisSS 028112, utg 3Waste water/Leach waterSuspended solids, Residue of ignitionGravimetry>5 mg/l
Water analysisSS 028113, utg 1Sludges/sedimentsDry matterGravimetry>20 mg/kg
Water analysisSS 028113, utg 1Sludges/sedimentsResidue of ignitionGravimetry>20 mg/kg
Water analysisSS-EN 872:2005Waste water/Leach waterSuspended solidsGravimetry>5 mg/l
Water analysisSS-EN ISO 10523:2012Waste water/Leach waterpHElectrode3 – 10
Water analysisSS-EN ISO 20236:2025ChemicalsTotal organic carbon, TOCCombustion1,0 – 200 mg/l
Water analysisSS-EN ISO 20236:2025Fresh waterNitrogen, total, TNbCombustion0,7-50 mg/l
Water analysisSS-EN ISO 20236:2025Fresh waterTotal organic carbon, TOCCombustion1,0 – 200 mg/l
Water analysisSS-EN ISO 20236:2025Waste water/Leach waterNitrogen, total, TNbCombustion0,7-50 mg/l
Water analysisSS-EN ISO 20236:2025Waste water/Leach waterTotal organic carbon, TOCCombustion1,0 – 200 mg/l

Regulations

ILAC G17:01/2021
ILAC Guidelines for Measurement Uncertainty in Testing
STAFS 2020:1
Swedacs föreskrifter och allmänna råd om ackreditering